Wednesday, September 08, 2010
Login
Register
Main Navigation
Home
The Science of ConShield
What is MIC Corrosion?
Source of Corrosion
Industry Use
Technical Information
Testimonials
Latest News
Sales Representatives
References
Contact Us
FAQ
Associations
What's New
Our new animation video explaining how Con
mic
Shield® works is now online. They say a picture is worth a thousand words. In this case, it's video! Click on the image above to visit "The Science of Con
mic
Shield®" page to
read more
.
Bill Shook, president of Conshield Technologies along with Tom Iseley, Professor & Director Purdue University, IUPUI explains Sulphide Corrosion in this informative news story.. Click the image above to
read more
This report details the successful testing through various agencies that has allowed limited field use of Con
mic
Shield® by the City of Indianapolis. Click on the image above to
read more
You are here:
Industry Use
Prevents Corrosion Before it Begins!
Industry Use of Con
mic
Shield®
New Concrete Pipe And Manholes
Concrete pipe is used more often than any other type of product in city sewer systems. Con
mic
Shield® keeps it from corroding for just a fraction of the cost of plastic liners or coatings. There is no special fabricating, welding or testing required at the plant or in the field with Con
mic
Shield® since it is precisely metered into the mix at the plant.
Shotcrete
Pipelines and tunnels that have already suffered from corrosion can be rehabilitated in place. Con
mic
Shield® is easily added to the mix water for both dry and wet shotcrete hand-spraying. Con
mic
Shield® is also incorporated into special mixes for centrifugally lining corroded pipe interiors for structural reinforcement and protection in one application. See Centrifugally Cast Concrete Pipe (CCCP) at
www.permaform.net
Poured-in-Place Structures
Con
mic
Shield® is an excellent choice for both new and rebuilt wet wells, lift stations, WWTP head works, clarifiers and similar concrete structures subjected to highly concentrated sulfide conditions. Metered into the mix at the ready-mix plant, Con
mic
Shield® is delivered as an integral part of the concrete when it is delivered to the job site. No spark testing, welding or adhesion tests are needed.
Rehabilitation
Con
mic
Shield® has performed successfully since its introduction in 1996 for the rehabilitation of heavily corroded manholes. Con
mic
Shield® eliminates bacterial growth while calcium aluminate cements can only slow bacterial growth. Con
mic
Shield® is far less expensive than coatings and Con
mic
Shield® will not delaminate, pinhole, peel or wash off. Structural reinforcement and corrosion protection is complete in one application.
Copyright 2010 by ConShield Technologies, Inc.
|
Terms of Use
|
Privacy Statement